Back to the list of connectors
Oracle/Sun Blade Chassis
Description
This connector provides hardware monitoring for the Sun Blade Chassis through the CMM SNMP Agent.
Connector ID: SunBladeChassis
This connector supersedes:
Target
Typical platform: Oracle/Sun Blade
Operating system: Out-of-Band
Prerequisites
Leverages: Sun Blade Chassis CMM SNMP Agent
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Examples
CLI
hws HOSTNAME -t management -f SunBladeChassis --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ SunBladeChassis ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The Oracle/Sun Blade Chassis connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get on the OID
1.3.6.1.4.1.42.2.70.101.1.1.2.1.5.2
must return a value that matches with the^/CH
regular expression
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Fan |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|
Voltage Sensor |
|
|
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}
No results.