Back to the list of connectors

Oracle/Sun ILOM (SNMP)

Description

This connector provides hardware monitoring for the Sun/Oracle Blade servers with ILOM cards via SNMP

Connector ID: SunILOMSNMP

This connector is superseded by:

This connector supersedes:

Target

Typical platform: Oracle/Sun

Operating systems: Out-of-Band, Storage System

Prerequisites

Leverages: Sun/Oracle ILOM SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t management -f SunILOMSNMP --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ SunILOMSNMP ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Oracle/Sun ILOM (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get on the OID 1.3.6.1.4.1.42.2.70.101.1.1.2.1.5.1 must return a non-empty value

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.enclosure.energy
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • model
  • serial_number
  • vendor
Processor
  • hw.status{hw.type="cpu",state="ok|degraded|failed"}
  • hw.status{hw.type="cpu",state="present"}
  • info
Fan
  • hw.fan.limit{limit_type="high.critical"}
  • hw.fan.limit{limit_type="high.degraded"}
  • hw.fan.speed
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • info
Memory Module
  • hw.memory.limit
  • hw.status{hw.type="memory",state="ok|degraded|failed"}
  • hw.status{hw.type="memory",state="present"}
  • info
  • model
  • serial_number
  • vendor
Other Device
  • hw.status{hw.type="other_device",state="ok|degraded|failed"}
  • hw.status{hw.type="other_device",state="present"}
  • info
  • device_type
Physical Disk
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="present"}
  • info
  • model
  • vendor
Power Supply
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
  • info
Temperature Sensor
  • hw.status{hw.type="temperature",state="ok|degraded|failed"}
  • hw.status{hw.type="temperature",state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
  • info
Voltage Sensor
  • hw.status{hw.type="voltage",state="ok|degraded|failed"}
  • hw.status{hw.type="voltage",state="present"}
  • hw.voltage
  • hw.voltage.limit{limit_type="high.critical"}
  • hw.voltage.limit{limit_type="low.critical"}
  • info
No results.