Back to the list of connectors
Oracle/Sun Solaris - Fault Manager - Memory and CPU
Description
This connector parses fmadm faulty command looking for faulty memory modules
Connector ID: SunFmadm
This connector is superseded by:
Target
Typical platform: Oracle/Sun
Operating system: Oracle Solaris
Prerequisites
Leverages: Sun Solaris system commands (fmadm)
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
/usr/sbin/fmadm
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the hwsagent account:
hwsagent ALL=(root) NOPASSWD: /usr/sbin/fmadm
Examples
CLI
hws HOSTNAME -t solaris -f SunFmadm --ssh -u USER --sudo-command-list /usr/sbin/fmadm
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: solaris
selectedConnectors: [ SunFmadm ] # Optional, to load only this connector
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
useSudo: true
useSudoCommands: [ "/usr/sbin/fmadm" ]
Connector Activation Criteria
The Oracle/Sun Solaris - Fault Manager - Memory and CPU connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is Oracle Solaris
- The command below succeeds on the monitored host
- Command:
/bin/uname -r
- Output contains:
5\.1[0-9]
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/usr/sbin/fmadm faulty;/usr/bin/echo errorlevel $?
- Output contains:
^errorlevel 0$
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/usr/sbin/fmadm config | grep cpumem
- Output contains:
active
(regex)
- Command:
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Memory Module |
|
|
Other Device |
|
|