Back to the list of connectors

Oracle Hardware Management Agent

Description

This connector provides hardware monitoring through the Oracle Hardware Management Pack which is pre-installed with Solaris and can be installed on Linux / Windows.

Connector ID: SunHwMon

This connector supersedes:

Target

Typical platform: Oracle/Sun

Operating systems: Microsoft Windows, Linux, Oracle Solaris

Prerequisites

Leverages: Oracle Hardware Management Pack

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t win -f SunHwMon --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ SunHwMon ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Oracle Hardware Management Agent connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.42.2.2.6.1.1.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.enclosure.energy
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • bios_version
  • model
  • serial_number
  • type
  • vendor
Disk Controller
  • hw.status{hw.type="disk_controller",state="ok|degraded|failed"}
  • hw.status{hw.type="disk_controller",state="present"}
  • firmware_version
  • serial_number
  • vendor
Processor
  • hw.status{hw.type="cpu",state="ok|degraded|failed"}
  • hw.status{hw.type="cpu",state="present"}
  • model
Fan
  • hw.fan.speed
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
    LED
    • hw.status{hw.type="led",state="ok|degraded|failed"}
    • hw.status{hw.type="led",state="present"}
      Logical Disk, RAID
      • hw.logical_disk.limit
      • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
      • hw.status{hw.type="logical_disk",state="present"}
      • raid_level
      Memory Module
      • hw.memory.limit
      • hw.status{hw.type="memory",state="ok|degraded|failed"}
      • hw.status{hw.type="memory",state="present"}
      • model
      Other Device
      • hw.status{hw.type="other_device",state="ok|degraded|failed"}
      • hw.status{hw.type="other_device",state="present"}
      • device_type
      Physical Disk
      • hw.physical_disk.size
      • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
      • hw.status{hw.type="physical_disk",state="present"}
      • info
      • model
      • serial_number
      • vendor
      Power Supply
      • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
      • hw.status{hw.type="power_supply",state="present"}
      • power_supply_type
      Temperature Sensor
      • hw.status{hw.type="temperature",state="ok|degraded|failed"}
      • hw.status{hw.type="temperature",state="present"}
      • hw.temperature
        Voltage Sensor
        • hw.status{hw.type="voltage",state="ok|degraded|failed"}
        • hw.status{hw.type="voltage",state="present"}
        • hw.voltage
          No results.