Back to the list of connectors

EMC Celerra/VNX Unified System (SSH)

Description

This connector provides hardware monitoring by connecting to the Control Server of EMC Celerra and EMC VNX Unified Systems.

Connector ID: EMCCelerra

This connector supersedes:

Target

Typical platforms: EMC Celerra, EMC VNX Unified

Operating system: Storage System

Prerequisites

Leverages: EMC naviseccli and nas_inventory utilities

Technology and protocols: System Commands

Examples

CLI

hws HOSTNAME -t storage -f EMCCelerra --ssh -u USER

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ EMCCelerra ] # Optional, to load only this connector
  ssh:
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt

Connector Activation Criteria

The EMC Celerra/VNX Unified System (SSH) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The command below succeeds on the monitored host
    • Command: /nas/bin/nas_inventory
    • Output contains: Error 2100 (regex)

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • serial_number
  • type
  • vendor
Processor
  • hw.status{hw.type="cpu",state="ok|degraded|failed"}
  • hw.status{hw.type="cpu",state="present"}
  • info
  • model
Logical Disk, RAID
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
  • raid_level
Memory Module
  • hw.memory.limit
  • hw.status{hw.type="memory",state="ok|degraded|failed"}
  • hw.status{hw.type="memory",state="present"}
  • info
  • model
  • serial_number
  • type
Network Card, FC Port
  • hw.network.bandwidth.limit
  • hw.network.up
  • hw.status{hw.type="network",state="ok|degraded|failed"}
  • hw.status{hw.type="network",state="present"}
  • info
Other Device
  • hw.status{hw.type="other_device",state="ok|degraded|failed"}
  • hw.status{hw.type="other_device",state="present"}
  • info
  • device_type
Physical Disk
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="present"}
  • info
  • firmware_version
  • model
  • vendor
Power Supply
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
  • info
  • power_supply_type