Back to the list of connectors
EMC Navisphere CLI (Global User)
Description
This connector provides hardware monitoring through EMC Navisphere CLI (naviseccli). The naviseccli must be installed on the system where the agent is running. This connector uses naviseccli to connect to the EMC VNX controller as a "Global User", i.e. with "Scope 1".
Connector ID: EMCNavisphereCLIGlobal
This connector is superseded by:
This connector supersedes:
Target
Typical platforms: EMC CLARiiON, EMC VNX
Operating system: Storage System
Prerequisites
Leverages: EMC naviseccli utility
Technology and protocols: System Commands
Examples
CLI
hws HOSTNAME -t storage -f EMCNavisphereCLIGlobal --ssh -u USER
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: storage
selectedConnectors: [ EMCNavisphereCLIGlobal ] # Optional, to load only this connector
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
Connector Activation Criteria
The EMC Navisphere CLI (Global User) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The command below succeeds on the agent host
- Command:
naviseccli -help
- Output contains:
Navisphere
(regex)
- Command:
- The command below succeeds on the agent host
- Command:
naviseccli -User %{USERNAME} -Password %{PASSWORD} -Address %{HOSTNAME} -Scope 0 getagent
- Output contains:
Agent Rev:
(regex)
- Command:
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Processor |
|
|
Logical Disk, RAID |
|
|
Memory Module |
|
|
Network Card, FC Port |
|
|
Other Device |
|
|
Physical Disk |
|
|
Power Supply |
|
|
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}
No results.