Back to the list of connectors

EMC uemcli (VNXe)

Description

This connector provides hardware monitoring for EMC VNXe Storage Systems through the uemcli command line utility.

Connector ID: EMCuemcli

This connector is superseded by:

Target

Typical platform: EMC VNXe

Operating system: Storage System

Prerequisites

Leverages: uemcli

Technology and protocols: System Commands

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t storage -f EMCuemcli --ssh -u USER

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ EMCuemcli ] # Optional, to load only this connector
  ssh:
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt

Connector Activation Criteria

The EMC uemcli (VNXe) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • Operating System is Storage System
  • The command below succeeds on the agent host
    • Command: uemcli -version | more
    • Output contains: Version: (regex)
  • The command below succeeds on the agent host
    • Command: uemcli -d %{HOSTNAME} -u %{USERNAME} -p %{PASSWORD} -sslPolicy accept /sys/general show | more
    • Output contains: Model (regex)

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • serial_number
  • type
  • vendor
Battery
  • hw.status{hw.type="battery",state="ok|degraded|failed"}
  • hw.status{hw.type="battery",state="present"}
    Fan
    • hw.status{hw.type="fan",state="ok|degraded|failed"}
    • hw.status{hw.type="fan",state="present"}
      Memory Module
      • hw.status{hw.type="memory",state="ok|degraded|failed"}
      • hw.status{hw.type="memory",state="present"}
        Network Card, FC Port
        • hw.network.up
        • hw.status{hw.type="network",state="ok|degraded|failed"}
        • hw.status{hw.type="network",state="present"}
          Other Device
          • hw.status{hw.type="other_device",state="ok|degraded|failed"}
          • hw.status{hw.type="other_device",state="present"}
          • device_type
          Physical Disk
          • hw.physical_disk.size
          • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
          • hw.status{hw.type="physical_disk",state="present"}
          • info
          • firmware_version
          • model
          • serial_number
          • vendor
          Power Supply
          • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
          • hw.status{hw.type="power_supply",state="present"}
            No results.