Hardware Fan
PATROL Class: MS_HW_FAN - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.
Monitors a specific fan. Monitoring fans is important since they ensure maintaining the right temperature for optimal functioning of the system.
Attributes (Parameters)
Name | PATROL Name | Units | Default Thresholds | Description |
---|---|---|---|---|
Present | Present | 0 = Missing 1 = Present |
ALARM |
Indicates whether the fan is found or not. Value set by fanColl. Type: Availability |
Speed | Speed | RPM | None | Speed of the corresponding fan (in revolutions/minute). An alert is triggered if the fan speed is too low for proper functioning. Value set by fanColl. Note: Alert thresholds are set automatically by Hardware Sentry which should not be customized or modified. Type: Statistics - Default graph |
Speed Percent | SpeedPercent | % of maximum speed | None | Speed of the corresponding fan in percentage of its maximal speed. Value set by fanColl. Note: Alert thresholds are set automatically by Hardware Sentry which should not be customized or modified. Type: Statistics |
Status | Status | 0 = OK 1 = Degraded 2 = Failed |
WARN ALARM |
Fan status. Value set by fanColl. Type: Availability - Default graph |
Status Information | StatusInformation | None | None | Additional (textual) information about the current status of the fan. Value set by fanColl. Type: Text |