Hardware Robotics

PATROL Class: MS_HW_ROBOTICS - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a specific robotic device. These instances are created under enclosures.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Error Count ErrorCount errors

 ALARM
if ≥ 1 errors

Number of errors encountered by the robotic device since the last reinitialization or since the last manual reset. This parameter is incremented each time an error occurs on this robotic device. An alert is raised automatically from the first detected error. The operator can reset the counter and clear the alert through the menu Acknowledge Error Count Alerts and Reset. Resetting the ErrorCount parameter can also be configured to be performed automatically.

Value set by roboticColl.

Type: Statistics - Default graph

Move Count MoveCount moves None

Number of moves performed by the robot.

Value set by roboticColl.

Type: Statistics

Present Present 0 = Missing
1 = Present

 ALARM
if = 0 (Missing)

Availability of the robotic device.

Value set by roboticColl.

Type: Availability

Status Status 0 = OK
1 = Degraded
2 = Failed

 WARN
if = 1 (Degraded)

 ALARM
if = 2 (Failed)

Robotic device status.

Value set by roboticColl.

Type: Availability - Default graph

Status Information StatusInformation None None

Additional (textual) information about the current status of the robotic device.

Value set by roboticColl.

Type: Text