Data Protector Databases
PATROL Class: HPO_DATABASE_CONTAINER - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.
Groups all backup catalog databases.
Attributes (Parameters)
Name | PATROL Name | Units | Default Thresholds | Description |
---|---|---|---|---|
Backup Elapsed | HPODatabaseBackupElapsed | hours | ALARM WARN |
Displays the elapsed time since the last successful catalog database backup. Value set by HPODatabaseCollector. Type: Statistics - Spikes expected - Baselining allowed - Default graph |
Exec Time | HPODatabaseCollectorExecTime | seconds | None | This is a standard parameter which monitors the collector execution time. It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below: %PSL pconfig("REPLACE", "/Runtime/HPO/<node-id>/HPODatabaseCollectorWarn", 3600); Type: Collection Status - Spikes expected |
Details | HPODatabaseDetails | N/A | None | Displays all data returned to the standard out from commands executed by the data collector. Value set by HPODatabaseCollector. Type: Text |
Status | HPODatabaseStatus | 0 = OK 1 = Suspicious 2 = Failure |
WARN ALARM |
Monitors the status of the Data Protector internal database (IDB). Value set by HPODatabaseCollector. Type: Availability - Spikes expected |