										Home
									
									
										
 - Storage Analyzer KM
 
Release Notes
This page lists the new features, improvements, changes and bug fixes in each version of Storage Analyzer.
Storage KM 1.11.00
1 Changes - Released 2025-08-19Fixed Issues
| ID | Description | 
|---|---|
| SKM-336 | Filers and Filesystems events are not enriched with information regarding the detected issue | 
Storage Intelligence 40
4 Changes - Released 2025-07-18Changes and Improvements
| ID | Description | 
|---|---|
| SI-470 | Dell EMC Isilon (REST) supports PowerScale | 
| SI-469 | Huawei OceanStor (REST): Added vStore information | 
| SI-468 | Dell EMC VMAX (REST): Ignore DiskGroup ID 512 to avoid job failure | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-464 | Dell EMC PowerMax v4 (REST): The values reported for storage system Capacity and Configured Capacity do not match those displayed in the Unisphere console | 
Storage Intelligence 39
2 Changes - Released 2025-06-23What's New
| ID | Description | 
|---|---|
| SI-460 | Added support for HPE Alletra 6000 storage systems | 
| SI-459 | Added support for HPE StoreOnce systems | 
Storage Intelligence 38
4 Changes - Released 2025-05-23What's New
| ID | Description | 
|---|---|
| SI-446 | Added support for Qumulo | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-453 | HPE Primera (WBEM) supports Alletra 9000 and Alletra MP series | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-451 | Oracle ZFS (REST): Processor Utilization is exceeding 100% | 
| SI-433 | Dell EMC PowerVault (REST): Discovery fails when a port is unplugged | 
Storage Intelligence 37
2 Changes - Released 2025-04-28What's New
| ID | Description | 
|---|---|
| SI-447 | Added support for Synology | 
| SI-413 | Added support for Huawei OceanStor Pacific 9000 Series | 
Storage Intelligence 36
2 Changes - Released 2025-03-20What's New
| ID | Description | 
|---|---|
| SI-440 | Huawei OceanStor (REST): Added NAS information | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-435 | Hitachi E Series, G Series (REST): Consumed and Available Capacity for Storage Systems and Storage Pools are now more accurate | 
Storage KM 1.10.00
2 Changes - Released 2025-03-03Fixed Issues
| ID | Description | 
|---|---|
| SKM-333 | Port address displays incorrect IQN address for Ethernet ports | 
| SKM-331 | The "Available Capacity" metric is not reported for the "Storage Filesystem" monitor | 
Storage Intelligence 35
3 Changes - Released 2025-02-24What's New
| ID | Description | 
|---|---|
| SI-431 | Added support for HPE MSA 1000/2000 Series | 
| SI-430 | Added support for Dell EMC PowerMax through Unisphere v10.1 or later via REST | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-434 | Huawei OceanStor (REST): Port metrics are not collected when a port is unplugged | 
Storage Intelligence 34
7 Changes - Released 2025-01-28Fixed Issues
| ID | Description | 
|---|---|
| SI-428 | IBM DS8000 (REST): The Storage System monitor is not properly discovered | 
| SI-427 | Huawei OceanStor (REST): Cookie management issues may lead to missing instances and inaccurate metrics | 
| SI-426 | Huawei OceanStor (REST): SAS ports are erroneously considered for license count | 
| SI-423 | Huawei OceanStor (REST): Management ports (MGMT) are erroneously considered for license count | 
| SI-421 | Oracle ZFS (REST): An HTTP error 404 causes the discovery to fail | 
| SI-420 | Oracle ZFS (REST): Storage System is not discovered when pools are exported | 
| SI-414 | Oracle ZFS (REST): Filesystems may be missing if they share the same name | 
Storage Intelligence 33
5 Changes - Released 2024-12-13What's New
| ID | Description | 
|---|---|
| SI-399 | Added support for IBM FlashSystem (9500 and 7300) via REST API | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-412 | Dell EMC Unity (REST): Disk Type is incorrect | 
| SI-411 | NetApp StorageGRID (REST): Capacity metrics reported for storage pools are not correct | 
| SI-409 | IBM DS8000 (REST): IBM Z hosts - Capacities for CDK Volumes and CKD Pools are not correct | 
| SI-408 | Dell EMC Isilon (REST): Discovery fails with `HTTPResponseException: null` when a cluster node is down | 
Storage Intelligence 32
6 Changes - Released 2024-10-21What's New
| ID | Description | 
|---|---|
| SI-401 | Dell EMC Unity (REST): Added NAS servers as Storage Filers | 
| SI-398 | Dell EMC Isilon (REST): Added Storage Filesystem monitor | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-400 | Dell EMC PowerMax v4 (REST): Added the Status parameter to the SKM_SYSTEM class | 
| SI-318 | Hitachi GUM (REST): Improved discovery and collect | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-388 | Oracle ZFS (REST), Dell EMC Avamar (REST), Dell EMC Unity (REST): Some status and type metrics are incorrect | 
| SI-387 | IBM DS8000 (REST): Volume capacity and status metrics are not collected when there are no hosts | 
Storage KM 1.9.00
1 Changes - Released 2024-08-28Changes and Improvements
| ID | Description | 
|---|---|
| SKM-324 | Storage Intelligence updated to version 31 | 
Storage Intelligence 31
3 Changes - Released 2024-08-14What's New
| ID | Description | 
|---|---|
| SI-379 | Added support for IBM Spectrum Protect (REST) | 
| SI-378 | Added support for Dell EMC Avamar (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-383 | Hitachi E Series, G Series (REST): The "Enable Hardware Monitoring" option is not available | 
Storage Intelligence 30
3 Changes - Released 2024-07-19What's New
| ID | Description | 
|---|---|
| SI-319 | Added support for Dell EMC VPLEX (REST) | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-374 | HPE Primera (WBEM): The calculation of the Processor Utilization parameter has been improved | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-375 | Ceph (REST): API calls may fail and trigger an HTTP Error 415 - Unsupported Media Type | 
Storage Intelligence 29
3 Changes - Released 2024-06-17What's New
| ID | Description | 
|---|---|
| SI-330 | Added support for IBM Spectrum Control (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-372 | IBM DS8000 (REST): An unexpected exception occurs upon the discovery of Storage Pools | 
| SI-371 | IBM DS8000 (REST): Lookup value is erroneously displayed as System Name | 
Storage Intelligence 28
4 Changes - Released 2024-05-15What's New
| ID | Description | 
|---|---|
| SI-327 | Added support for Dell EMC PowerProtect DD (REST) | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-336 | IBM DS8000 (REST): The volume serial number (VOLSER) is added to the Storage Volume's name for better identification | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-364 | Pure Storage FlashArray (REST v2.4+): Collect failure when getting APIVersion | 
| SI-290 | HPE Primera (WBEM): The calculation of some metrics is modified to match the values displayed in Infosight | 
Storage KM 1.8.00
2 Changes - Released 2024-05-03Changes and Improvements
| ID | Description | 
|---|---|
| SKM-310 | Parameters and Monitors Information is not displayed if their value cannot be retrieved | 
Fixed Issues
| ID | Description | 
|---|---|
| SKM-315 | A NullPointerException is generated when monitoring NAS storage systems | 
Storage Intelligence 27
6 Changes - Released 2024-05-02Changes and Improvements
| ID | Description | 
|---|---|
| SI-361 | Dell EMC PowerVault (REST): The CacheHitRatio metric for Controllers is more accurate | 
| SI-360 | Dell EMC PowerVault (REST): The LinkStatus metric for Ports is more accurate | 
| SI-359 | Dell EMC PowerVault (REST): Added Status and StatusInformation metrics to Ports | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-362 | Dell EMC PowerVault (REST): Collection failure when LinkSpeed cannot be retrieved | 
| SI-356 | Dell EMC PowerVault (REST): Collection failure caused by a JdbcSQLDataException | 
| SI-353 | NetApp StorageGRID (REST): Response Time values are displayed in seconds instead of milliseconds | 
Storage Intelligence 26
2 Changes - Released 2024-04-15What's New
| ID | Description | 
|---|---|
| SI-329 | Added support for NetApp StorageGRID | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-343 | IBM DS8000 (REST) and Oracle ZFS (REST): The Link Status parameter is incorrectly reported | 
Storage Intelligence 25
5 Changes - Released 2024-03-15What's New
| ID | Description | 
|---|---|
| SI-323 | Added support for IBM DS8000 Series (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-340 | Pure Storage FlashBlade (REST): Storage systems' size is wrong | 
| SI-337 | Oracle ZFS (REST): "Capacity", "Consumed Capacity Percentage" and "Available Capacity Percentage" metrics for file systems are not correct | 
| SI-333 | Pure Storage FlashBlade (REST): The "Consumed Capacity Percentage" metric for file systems is greater than 100% | 
| SI-331 | IBM DS888x (WBEM): Storage Pools and Storage Volumes are not discovered | 
Storage KM 1.7.00
1 Changes - Released 2024-01-25Changes and Improvements
| ID | Description | 
|---|---|
| SKM-301 | The performance of the CollectionHub has been improved | 
Storage Intelligence 24
2 Changes - Released 2023-12-18What's New
| ID | Description | 
|---|---|
| SI-310 | Added support for Oracle ZFS (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-320 | Huawei OceanStor (REST): Storage system's Available Capacity and Consumed Capacity metrics are missing when the storage system is in NAS mode | 
Storage Intelligence 23
2 Changes - Released 2023-11-17What's New
| ID | Description | 
|---|---|
| SI-300 | Added support for Pure Storage FlashBlade (REST) storage systems | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-316 | Dell EMC PowerMax v4 (REST): The Configured Capacity and Capacity metrics for Storage Pools are more accurate | 
Storage KM 1.6.00
8 Changes - Released 2023-11-10Changes and Improvements
| ID | Description | 
|---|---|
| SKM-291 | Report thresholds via the "SKM_q; thresholdsReport(endpointList)" command | 
| SKM-281 | Report Device Name in TrueSight/BHOM (MetaFQDN) via the "SKM_q; endpointsInfo()" command | 
| SKM-277 | Web UI: Ability to enable debug for specific endpoints | 
| SKM-272 | Debug logs are compressed by default at the end of debug window | 
Fixed Issues
| ID | Description | 
|---|---|
| SKM-289 | Incorrect thresholds are set on the Controllers' Status parameter | 
| SKM-280 | Devices are no longer created in TrueSight because the endpoint's MetaFQDN is no longer set | 
| SKM-276 | The Monitor Type of some PATROL classes' Containers are erroneously identified as Monitors instead of Containers | 
| SKM-235 | Remove the Count parameter from the SKM_FILESYSTEM_CONT class | 
Storage Intelligence 22
1 Changes - Released 2023-11-06What's New
| ID | Description | 
|---|---|
| SI-296 | Added support for Dell EMC PowerMax v4 (REST) | 
Storage Intelligence 21
1 Changes - Released 2023-10-16Changes and Improvements
| ID | Description | 
|---|---|
| SI-311 | HPE Primera (WBEM): Added a new metric to report the Queue Length value for Storage Volumes | 
Storage Intelligence 20
4 Changes - Released 2023-09-18What's New
| ID | Description | 
|---|---|
| SI-268 | Added support for NetApp Filers based on ONTAP REST API | 
| SI-267 | Added support for NetApp Filers based on Active IQ Unified Manager REST API | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-301 | NetApp E-Series (REST): Some classes such as SKM_SYSTEM, SKM_PORT, SKM_CONTROLLER are not discovered or collected | 
| SI-293 | Dell EMC VMAX (REST): Reported values for Configured Capacity and Subscribed Capacity metrics do not match the values displayed in the Unisphere UI | 
Storage Intelligence 19
5 Changes - Released 2023-07-18What's New
| ID | Description | 
|---|---|
| SI-278 | Added support for Fujitsu Eternus AF/DX series (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-292 | Dell EMC ScaleIO (REST): Some capacity metrics are not collected for storage systems, storage pools and storage volumes | 
| SI-285 | Dell EMC VMAX (REST) and Dell EMC Unity (REST): All volumes may not be collected | 
| SI-282 | Dell EMC PowerStore (REST): Values for Configured Capacity and Subscribed Capacity metrics are missing | 
| SI-279 | Huawei OceanStor (REST): Unable to collect data from physical disks with unknown type | 
Storage Intelligence 18
1 Changes - Released 2023-05-11Fixed Issues
| ID | Description | 
|---|---|
| SI-270 | Huawei OceanStor (REST): Missing devices reported due to expired token | 
Storage KM 1.5.00
8 Changes - Released 2023-05-11Changes and Improvements
| ID | Description | 
|---|---|
| SKM-264 | ClientTimeout default value is increased to 30 minutes | 
| SKM-259 | Disable Missing Device Detection can be activated from a CMA policy | 
| SKM-258 | Added two configuration variables to customize queries retry delays | 
Fixed Issues
| ID | Description | 
|---|---|
| SKM-262 | Vulnerability CVE-2021-44832 in SI Launcher | 
| SKM-257 | An incorrect threshold is set on the Present parameter of Controllers | 
| SKM-250 | Dell EMC VMAX (WBEM): Monitors are incorrectly attached to the SMI-S provider device instead of the storage system | 
| SKM-243 | IBM DS888x (WBEM) and Dell EMC VMAX (WBEM): The Status parameter are always set to 1 (Degraded) | 
| SKM-221 | Huawei OceanStor (REST): Missing and null objects are visible | 
Storage Intelligence 17
6 Changes - Released 2023-04-14What's New
| ID | Description | 
|---|---|
| SI-260 | Added support for Hitachi GUM (REST) | 
| SI-242 | Added support for Scality Ring (REST) | 
| SI-217 | Added support for Hitachi E Series (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-269 | Dell EMC PowerStore (REST) stops working after the REST API is upgraded to v.3.x | 
| SI-265 | Dell EMC Isilon (REST): Storage Pools IDs are not unique | 
| SI-258 | Dell EMC VMAX (REST): Unisphere v10 is not supported | 
Storage Intelligence 16
1 Changes - Released 2023-02-20Fixed Issues
| ID | Description | 
|---|---|
| SI-262 | Dell EMC Isilon (REST): Volume IDs are not unique | 
Storage Intelligence 15
3 Changes - Released 2023-01-19What's New
| ID | Description | 
|---|---|
| SI-237 | HPE Primera (WBEM): Full support for HPE Primera and HP 3PAR StoreServ systems | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-207 | Dell EMC SC Series (REST): Added the possibility to migrate from Dell Compellent ETL to Storage All In One ETL | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-240 | Dell EMC VMAX (REST): Connection times out while collecting volumes' metrics | 
Storage KM 1.4.01
1 Changes - Released 2022-11-14Fixed Issues
| ID | Description | 
|---|---|
| SKM-239 | Security vulnerability in Swagger UI (OpenAPI) when displaying the documentation through Monitoring Studio | 
Storage Intelligence 13
1 Changes - Released 2022-11-10Changes and Improvements
| ID | Description | 
|---|---|
| SI-236 | Dell EMC PowerVault (REST): Add the ability to enable hardware monitoring | 
Storage KM 1.4.00
4 Changes - Released 2022-09-26Changes and Improvements
| ID | Description | 
|---|---|
| SKM-231 | Operation timeout is now configurable via the SI Launcher | 
| SKM-227 | Discovery timeout is customizable via the "endpointSiliciumLockTimeout" variable (Default increased to 3600 seconds) | 
| SKM-226 | Pure Storage FlashArray Series (REST v2.4+): Added token authentication to enable Hardware monitoring | 
| SKM-218 | Storage Analyzer KM now handles File Systems | 
Storage Intelligence 12
11 Changes - Released 2022-09-22What's New
| ID | Description | 
|---|---|
| SI-211 | Added support for Dell EMC PowerVault (REST) | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-226 | Dell EMC PowerStore (REST) and Dell EMC Unity (REST) require version 1.10.00 or higher of the Storage All-in-One engine | 
| SI-215 | Pure Storage (REST): Capacity to manage environments with more than 500 monitored volumes | 
| SI-201 | Dell EMC Unity (REST): Addition of new metrics for Storage Systems, Storage Pools and Storage Volumes | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-229 | Dell EMC SC Series (REST): Data collect is stopped when the REST API encounters a volume with a missing name | 
| SI-227 | Huawei OceanStor (REST): A NullPointerException is triggered when no iSCSI port is reported | 
| SI-222 | NetApp E-Series (REST): Discovery failure caused by HTTPResponseException or JdbcSQLSyntaxErrorException | 
| SI-221 | Dell EMC VMAX (REST): Controllers' Processor Utilization reports values higher than 100 % | 
| SI-209 | Pure Storage FlashArray (REST v2.4+): "OutOfMemoryError: GC overhead limit exceeded" causes the data collect to fail | 
| SI-206 | Dell EMC Isilon (REST): Processor Utilization (%) on Controllers reports values above 100 % | 
| SI-195 | Hitachi G Series (REST): A NullPointerException is triggered when no iSCSI port is reported | 
Storage Intelligence 10
3 Changes - Released 2022-03-23What's New
| ID | Description | 
|---|---|
| SI-84 | Added support for Dell EMC PowerStore (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-197 | Dell EMC VMAX (REST): Data collection for volumes may fail when multiple systems are attached to the same Dell EMC Unisphere | 
| SI-191 | Dell EMC SC Series (REST): "HTTP Error 204"causes the adapter to stop discovering the Storage Systems | 
Storage Intelligence 9
6 Changes - Released 2022-02-18What's New
| ID | Description | 
|---|---|
| SI-190 | Added support for Dell EMC PowerFlex/ScaleIO (REST) | 
| SI-180 | Added support for Dell EMC Unity (REST) | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-192 | H2 database upgraded from v1.4.199 to v2.1.210 | 
| SI-186 | Jackson library upgraded to version 2.13.1 | 
| SI-182 | Remote systems are no longer supported for Dell EMC VMAX/PowerMax (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-179 | Dell EMC SC Series (REST): Port discovery fails due to an empty Speed string | 
Storage KM 1.3.00
2 Changes - Released 2021-12-22Changes and Improvements
| ID | Description | 
|---|---|
| SKM-216 | Log4Shell Vulnerability: Update log4j version to 2.17.0 in the troubleshooting tool | 
| SKM-211 | Agent-side collection can be deactivated from the monitoring policy | 
Storage Intelligence 8
6 Changes - Released 2021-08-26What's New
| ID | Description | 
|---|---|
| SI-163 | Added support for Huawei OceanStor (REST) | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-176 | Replace Helix Capacity Optimization with Helix Continuous Optimization | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-167 | Dell EMC SC Series (REST): Cannot connect directly to the Dell EMC SC Series systems | 
| SI-166 | Hitachi G-Series (REST): Storage systems are not created as separate devices in TrueSight/Helix OM | 
| SI-165 | Dell EMC VMAX (REST): Storage systems are not created as separate devices in TrueSight/Helix OM | 
| SI-164 | Dell EMC VMAX (REST): Discovery fails when the number of volumes is lower than 1000 | 
Storage Intelligence 7
1 Changes - Released 2021-04-22Changes and Improvements
| ID | Description | 
|---|---|
| SI-160 | Ceph Adapter: Added Vendor information to the Storage System properties (Storage Box) | 
Storage Intelligence 6
5 Changes - Released 2021-03-15What's New
| ID | Description | 
|---|---|
| SI-129 | Added support for Pure Storage REST API v2.4+ | 
| SI-107 | Added support for Dell EMC VMAX/PowerMax (REST) | 
| SI-68 | Added support for Hitachi G Series (REST) | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-149 | The Licence Count value for Dell EMC Isilon storage systems erroneously reports 0 | 
| SI-132 | Ceph Adapter: Errors 400 cause the collect to stop | 
Storage KM 1.2.00
7 Changes - Released 2021-03-15Changes and Improvements
| ID | Description | 
|---|---|
| SKM-191 | The KM triggers an alarm on the Collection Status parameter when the Storage Intelligence Adapter and the KM versions are not compatible | 
| SKM-177 | SKM is delivered with Storage Intelligence Library version 6 | 
| SKM-175 | Ability to Hide Volumes | 
| SKM-173 | Add API Token choice for Endpoint Connection Credentials | 
Fixed Issues
| ID | Description | 
|---|---|
| SKM-196 | Bad handling of white spaces in file paths prevents the KM to monitor Endpoints | 
| SKM-187 | The Storage Intelligence Adapter for existing Endpoint cannot be changed | 
| SKM-184 | Increased Port Number range in CMA Endpoint Policy | 
Storage KM 1.1.00
6 Changes - Released 2020-11-04What's New
| ID | Description | 
|---|---|
| SKM-138 | Integrate hardware monitoring through the Hardware Sentry KM | 
Changes and Improvements
| ID | Description | 
|---|---|
| SKM-160 | A specific Storage Intelligence Adapter can now be manually specified in the CMA interface | 
| SKM-155 | The default content of the events generated upon storage alerts refers to the device to which the object is attached | 
| SKM-152 | Instances of the SKM_SYSTEM class now create devices in TrueSight | 
Fixed Issues
| ID | Description | 
|---|---|
| SKM-163 | Response Time parameter values not always accurate for Netapp-Solidfire-REST, DellEMC-VMAX-WBEM and IBM-DS8880-WBEM platforms | 
| SKM-151 | Instance properties are not displayed in Monitoring Studio Web UI for SKM endpoints | 
Storage Intelligence 5
7 Changes - Released 2020-11-03What's New
| ID | Description | 
|---|---|
| SI-89 | Storage Intelligence Adapters contain hardware connector information in order to trigger hardware monitoring if configured by the user | 
| SI-74 | New metrics added to Storage Intelligence Adapters | 
Changes and Improvements
| ID | Description | 
|---|---|
| SI-124 | Add support for IBM DS888x (WBEM) | 
| SI-111 | Rename Red Hat Ceph (REST) to Ceph (REST) | 
| SI-83 | NetApp SolidFire (REST): The controller's memory size should report the sum of all available memory values | 
| SI-37 | Add monitoring metrics in IBM DS 888x .si file | 
Fixed Issues
| ID | Description | 
|---|---|
| SI-55 | ScaleIO - Operations and Rate are not correcly computed | 
Storage Intelligence 3
3 Changes - Released 2020-08-21Changes and Improvements
| ID | Description | 
|---|---|
| SI-81 | Add support for Dell EMC ScaleIO (REST) | 
| SI-53 | Add support for Dell EMC SC Series (REST) | 
| SI-14 | Add support for IBM Spectrum Scale (REST) | 