Add a Connection...
|
Enables you to add a connection to a Hitachi Device Manager/embedded SMI-S provider.
|
Reporting> Disk Arrays Activity...
|
Enables you to configure and generate a report on a disk array activity.
|
Reporting > Controllers Activity...
|
Enables you to configure and generate a report on a controller activity.
|
Reporting > Fiber Ports Activity...
|
Enables you to configure and generate a report on a fiber port activity.
|
Reporting > Storage Pools Activity...
|
Enables you to configure and generate a report on a storage pool activity.
|
Reporting > Volumes Activity...
|
Enables you to configure and generate a report on a volume activity.
|
Reporting > LUNs Owning Controller Table...
|
Enables you to configure and generate a table identifying which controllers owns which LUN.
|
Reporting > LUNs Mapping Table...
|
Enables you to configure and generate a table listing mapped and unmapped LUNs.
|
Reporting > Per Host Storage Allocation
|
Enables you to generate a report on the volume of storage allocated to each monitored host.
|
Reporting > Per LUN Storage Allocation
|
Enables you to generate a report on the volume of storage allocated to each monitored LUN.
|
Search WWN/IQN...
|
Enables you to find any component based on its complete or partial World Wide Name or IQN.
|
KM Settings > Java Settings...
|
Enables you to define which Java instance is to be used by the KM.
|
KM settings > Alert Actions
|
Enables you to select the Alert Actions (different methods of notification) to be executed by the KM when a parameter breaches its threshold.
|
KM Settings > Debug...
|
Activates or deactivates the debug mode. The debug Mode displays debug messages in the PATROL System Output Window or saves it in a file if you enter the file path.
|
KM settings >Additional Settings > Threshold Mechanism Selection
|
Allows you to select the threshold mechanism:
• | Automatic (by default): the KM determines the mode of threshold management best suited to the system. The different modes are: |
• | Tuning: the KM uses the internal PATROL mechanism to set thresholds |
• | Event Management: the KM automatically sets thresholds through the Event Management |
• | No thresholds: the KM does not set any thresholds and lets you specify them manually. |
|
KM Settings > Additional Settings > Restore Monitoring...
|
Brings up the "Restore Monitoring" wizard to restore one or several objects after their monitoring has been stopped.
|
Trigger a KM Discovery
|
Enables you to trigger a forced discovery and rediscover the hardware devices of the monitored system.
|
Pause All
|
Pauses the monitoring process.
|
Resume All
|
Resumes the monitoring of all objects after it has been paused.
|
Reinitialize KM...
|
Triggers a complete re-initialization of the KM. Customized settings are lost unless specified otherwise in the Reinitialize wizard.
|
About...
|
States basic product information and BMC Software support contact information.
|